Range
Native interval plates keep point estimates, supplied ranges, raw denominators and missing interpretation visible together.
Design study · 4 slides
Using Claude Code or Codex? Install the free presentation skill.
Source and instructions
Source notes
FROZEN FICTIONAL TWO-GROUP READOUT · RANGE Audience: a product review group. Purpose: inspect a fictional result and decide what evidence is still required before a rollout decision. This is toy data, not a real experiment or customer result. Group labels:control and treatment. Each has400trials, not necessarily400unique people. Control:180successes/400trials=45%. Treatment:212successes/400trials=53%. Observed difference:treatment minus control=8percentage points,32more successful trials in these equal-size groups. Do not turn percentagepoints into relativepercent or uniquepeople. A source-supplied interval for the difference is+1to+15percentagepoints. Its confidencelevel and calculationmethod are not supplied. Preserve it as supplied; do not calculate a replacement, label it95%, declare statisticalsignificance or infer sample sufficiency. Randomization, causalidentification and populationrepresentativeness are not established by thisbrief. Retention and error-rate guardrail results are not supplied. Missingresult doesnot establish that something was not measured, is zero or is safe. No overallwinner or rollout approval is supplied. Source recommendation:defer the rollout decision until guardrail results and interval interpretation are reviewed. No approver/date is supplied; do not invent them. Four slides:observed8ppdifference and suppliedinterval; matchedcounts/denominators; intervalinterpretation and unknownmethod; decisiongate with missingguardrailresults. The interval plot uses one linear differenceaxis from−5to+20percentagepoints, visible zero, point+8 and endpoints+1/+15. All values stay in ordinaryselectabletext. Nativeplot only; optionalimagery must not replace evidence.
Design instructions
Range: an evidence-led interval language in near-white #fbfcff, navy #162d47, cobalt #285ad8, pale blue #dce7fc and restrained rust #a34112. Lead with a zero-referenced native interval plot, then put raw counts beside comparable rate strips, expose missing interpretation and end at the supported decision gate. Large Arial headlines and precise unit labels should make the point estimate, range and unknowns equally inspectable. Use one linear axis and retain supplied endpoints, denominators and periods; do not convert percentage points into relative percentages or unique people. An interval without its method is not permission to invent a confidence level or significance claim. Adapt this method to the supplied evidence, not this trial or its values. Native plots and ordinary-text values remain complete without imagery. Optional image generation may supply labelled conceptual context only when useful and available; if unavailable or failed, continue with the full native interval/count/decision composition, leaving no placeholders. Preserve uncertainty and the source recommendation rather than forcing a winner.
Use my supplied content and the format I requested. Keep its facts, numbers, denominators, uncertainty and conclusion. Do not inherit the example deck’s story, figures or recommendation. The visual direction guides design; the audience and argument determine the slide sequence.
Check the tools available in this session. When an image would improve the presentation and a suitable generation tool is available, generate an original image or use an asset I am authorized to supply. If optional generation is unavailable or fails, continue with a complete image-free composition. Reclaim the space, leave no placeholders, and do not ask me to enable a tool or delay the deck for optional imagery. Mention a failure in the handoff rather than on audience-facing slides. If I explicitly require a particular image, preserve that requirement and explain any unmet dependency.
Keep text and evidence selectable. For HTML, use one self-contained static document with embedded CSS, compressed data images and licensed embedded fonts when needed; do not add scripts, forms, remote calls or authored slide controls. Preserve font licenses and asset provenance. Label conceptual or generated imagery when it could be mistaken for real product, customer or event evidence. Never invent a product screenshot to prove a feature.
Render every slide and inspect the actual result before handing it over. Check crop, contrast, type hierarchy, labels, overflow and source fidelity. Use at least 4.5:1 contrast for body text and 3:1 for large text. Check the destination’s file/data-image limits before any separately authorized publication. If visual checking is unavailable, say so in the handoff.About this design study
Four slides carry a fictional two-group readout with matched trial counts, an eight-percentage-point observed difference and unresolved interval and guardrail evidence. Independently authored fictional evidence readout using native plots. The supplied interval has no supplied confidence level or method, and the example establishes neither a causal result, statistical significance nor rollout approval.
